Through-wall mounting form
Compact drive set apart by its mounting form, not by power alone.
1 / 10
Variable Frequency Drive
Compact VFD with Through-Wall Mounting · 15–400kW
Compact drive set apart by its mounting form, not by power alone.
Supply: Three-phase 220 V 2T models and 380 V 4T models (model-dependent); 380V(-15%)~480V(+10%) for applicable 4T models.
Compact drive set apart by its mounting form, not by power alone.
Vector 0u2013300 Hz, V/F 0u20133200 Hz; carrier 0.5u201316 kHz.
SVC 1:100 / FVC 1:1000; accuracy u00b10.5% / u00b10.02%.
Overload 150%/60s, 180%/3s; RS-485 Modbus standard, CANopen optional.
| Item | Value |
|---|---|
| Series | ES530 compact VFD with through-wall mounting |
| Power range | 15u2013400 kW (selection table) |
| Positioning | Compact drive set apart by its mounting form, not by power alone. |
| Supply | Three-phase 220 V 2T models and 380 V 4T models (model-dependent); 380V(-15%)~480V(+10%) for applicable 4T models. |
| Max frequency | Vector 0u2013300 Hz; V/F 0u20133200 Hz |
| Carrier | 0.5u201316 kHz |
| Speed range | SVC 1:100; FVC 1:1000 |
| Accuracy | u00b10.5% (SVC); u00b10.02% (FVC) |
| Overload | 150% / 60 s; 180% / 3 s |
| Communication | RS-485 Modbus standard; CANopen optional |
| Warranty (manual) | 18 months from factory date (body barcode) |
| Model | Power capacity (kVA) | Input current (A) | Output current (A) | Motor (kW) |
|---|---|---|---|---|
| ES530-2T15G | 40 | 62 | 60 | 15 |
| ES530-2T18.5G | 57 | 76 | 75 | 18.5 |
| ES530-2T22G | 69 | 92 | 91 | 22 |
| ES530-2T30G | 85 | 113 | 112 | 30 |
| ES530-2T37G | 114 | 157 | 150 | 37 |
| ES530-2T45G | 134 | 180 | 176 | 45 |
| ES530-2T55G | 160 | 214 | 210 | 55 |
| ES530-2T75G | 231 | 307 | 304 | 75 |
| Model | Power capacity (kVA) | Input current (A) | Output current (A) | Motor (kW) |
|---|---|---|---|---|
| ES530-4T15GB | 21 | 35 | 32 | 15 |
| ES530-4T18.5GB | 24 | 38.5 | 37 | 18.5 |
| ES530-4T22GB | 30 | 46.5 | 45 | 22 |
| ES530-4T30G | 40 | 62.5 | 60 | 30 |
| ES530-4T37G | 57 | 76.0 | 75 | 37 |
| ES530-4T45G | 69 | 92.0 | 91 | 45 |
| ES530-4T55G | 85 | 113 | 112 | 55 |
| ES530-4T75G | 114 | 157 | 150 | 75 |
| ES530-4T90G | 134 | 180 | 176 | 90 |
| ES530-4T110G | 160 | 214 | 210 | 110 |
| ES530-4T132G | 192 | 256 | 253 | 132 |
| ES530-4T160G | 231 | 307 | 304 | 160 |
| ES530-4T200G | 250 | 385 | 377 | 200 |
| ES530-4T250G | 355 | 468 | 465 | 250 |
| ES530-4T315G | 445 | 590 | 580 | 315 |
| ES530-4T400G | 565 | 785 | 725 | 400 |
Dimensions for through-wall C-frame models are available in the user manual.
| Frame (power) | W (mm) | H (mm) | D (mm) | W1 (mm) | H1 (mm) | Hole | Notes |
|---|---|---|---|---|---|---|---|
| D03 (15u201318.5 kW) | 217 | 335 | 194 | 140 | 324 | u03a67 | M5 terminals |
| D04/D05 (22u201330 kW) | 228 | 361 | 203.5 | 139 | 349 | u03a67 | M5 |
| D06 (30u201345 kW) | 285 | 463 | 224 | 235 | 447 | u03a67 | M8 |
| D07 (45u201375 kW) | 305 | 613 | 294 | 200 | 592 | u03a610 | M8 |
| D08 (90u2013132 kW) | 400 | 753 | 293 | 280 | 731.5 | u03a610 | M12 |
| D09 (160u2013220 kW) | 520 | 1219 | 343 | 190 | 836.5 | u03a612 | M12 |
| D10 (250u2013355 kW) | 800 | 1172 | 412 | 300 | 1143 | u03a614 | M12 |
| D11 (400u2013710 class) | 1080 | 1800 | 500 | 310 | u2014 | u03a612 | M12 |
| C03P (15u201318.5 kW) | 180 | 280 | 180.6 | 166 | 266 | u03a66 | Through-wall |
| C07 (45u201355 kW) | 300 | 542 | 268.5 | 245 | 523 | u03a610 | Through-wall |
When heat must dump behind the panel and the drive sits flush in the door or wall.
Pumps, fans, and machinery that outgrow mini frames but still want a compact outline.
SVC/FVC accuracy and overload headroom for intermittent heavy torque.
Standard RS-485 Modbus with optional CANopen for coordinated lines.
Tell us your supply voltage, motor power, and application. We will recommend the right ES series drive.
Share your project details so our team can review your inquiry.